DualSun heats up Ocean Reef, WA

Case Studies

Dualsun Heats Up Ocean Reef Wa

System Installed

Heatseeker DualSun hybrid PV/T solar system

Solar Collectors

10.08kWp & 28.58Wth DualSun PV/T collector (36 x 280Wp & 794Wth panels)

Inverter

Fronius 8.6kw Single Phase Inverter

Initially wanting to remove their existing solar pool heating to make way for a new PV solar system to help reduce their rising energy bills, the customer contacted Supreme Heating upon learning about Heatseeker DualSun.

Impressed by the two-in-one solution that Heatseeker DualSun provides, the customer
saw an opportunity to reduce their energy expenses without having to sacrifice their solar pool heating.

Evaluating the customer’s energy needs and pool heating requirements, Supreme Heating proposed a 10.08kWp & 28.58Wth system consisting of 36 Heatseeker DualSun panels.

The system design was comprised of 18 panels on the North East facing roof and 18 panels on the North West facing roof, taking advantage of exposure to the sun throughout the entire day.

With an average thermal output of 170kWh/day, the system provides ample coverage to adequately heat the customers 60,000L in-ground swimming pool to average
temperatures of 28°C to 30°C throughout the swimming season between the months of September and April.

The Heatseeker DualSun system is also capable of generating an average of 52kWh/day of electricity, covering over 100% of the customer’s $4,200 worth of annual energy expenses.

With average energy savings of $7,395 per annum, the customer can expect that their
Heatseeker DualSun system to pay for itself within just over 5 years, based on current
energy prices.

The equivalent cost of using an inverter heat pump to create the same energy outputs of the solar system would be $2,709, negating the benefit of the electrical savings provided by a standard PV system.

1 Year

supreme heating

18.98 MWh

IN PV ELECTRICAL PRODUCTION

supreme heating

61.92 MWh

IN HEATED WATER PRODUCTION

supreme heating

$7,395

SAVED IN COMBINED ENERGY EXPENSES

20 Years

supreme heating

379.6 MWh

IN PV ELECTRICAL PRODUCTION

supreme heating

1,238 MWh

IN HEATED WATER PRODUCTION

supreme heating

$147,900

SAVED IN COMBINED ENERGY EXPENSES

Savings data based on the alternative use of an inverter heat pump with a COP of 6 and an electricity tariff of 25c/kWh heating the pool from September to April to temperatures of 28-30°C. Savings data does not account for inflation.